    \file    main.c
    \brief   RTC calendar demo

    \version 2025-08-20, V3.3.2, demo for GD32F4xx
*/

/*
    Copyright (c) 2024, GigaDevice Semiconductor Inc


    Redistribution and use in source and binary forms, with or without modification, 
are permitted provided that the following conditions are met:

    1. Redistributions of source code must retain the above copyright notice, this 
       list of conditions and the following disclaimer.
    2. Redistributions in binary form must reproduce the above copyright notice, 
       this list of conditions and the following disclaimer in the documentation 
       and/or other materials provided with the distribution.
    3. Neither the name of the copyright holder nor the names of its contributors 
       may be used to endorse or promote products derived from this software without 
       specific prior written permission.

    THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS "AS IS" 
AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED 
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED. 
IN NO EVENT SHALL THE COPYRIGHT HOLDER OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, 
INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT 
NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR 
PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, 
WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) 
ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY 
OF SUCH DAMAGE.
*/ 


  This demo is based on the GD32f470z-EVAL-V1.0 board, it explains how 
to configure the RTC module. In this demo, RTC peripheral is configured to keep
time.
  
  The RTC clock source can be chose to LXTAL or IRC32K by uncomment the corresponding 
define in main file. And the HyperTerminal should be connected to the evaluation 
board via USART0. The vbat bin on the board should connect to the CR1220 battery.
  
  After start-up,get key value from BKP data register or bit RTCSRC of backup domain 
control register. If the value is not correct, the program will ask to set the time and 
alarm value on the HyperTerminal. If the key value is correct, the time will be displayed 
on the HyperTerminal.

  Then LED1 and LED2 is turned on.
  
  The RTC module is in the Backup Domain, and is not reset by the system reset or 
power reset. 